Pages

Tuesday, January 10, 2012

3D32B80D topsvcs NIM thread blocked

topsvcs NIM thread blocked

---------------------------------------------------------------------------
LABEL: TS_NIM_ERROR_STUCK_
IDENTIFIER: 3D32B80D

Date/Time: Tue Jan 3 15:27:17 EST 2012
Sequence Number: 13148
Machine Id: 00F631C54C00
Node Id: xxxx
Class: S
Type: PERM
WPAR: Global
Resource Name: topsvcs

Description
NIM thread blocked

Probable Causes
A thread in a Topology Services Network Interface Module (NIM) process
was blocked
Topology Services NIM process cannot get timely access to CPU
The system clock was set forward

User Causes
Excessive memory consumption is causing high memory contention
Excessive disk I/O is causing high memory contention
The system clock was manually set forward

Recommended Actions
Examine I/O and memory activity on the system
Reduce load on the system
Tune virtual memory parameters
Call IBM Service if problem persists

Failure Causes
Excessive virtual memory activity prevents NIM from making progress
Excessive disk I/O traffic is interfering with paging I/O

Recommended Actions
Examine I/O and memory activity on the system
Reduce load on the system
Tune virtual memory parameters
Call IBM Service if problem persists

Detail Data
DETECTING MODULE
rsct,nim_control.C,1.39.1.26,6457
ERROR ID
6BUfAx.SGq.D/chl0uCE.d/...................
REFERENCE CODE

Thread which was blocked
receive thread
Interval in seconds during which process was blocked
10
Interface name
en12
----
You can ignore the message.
It might be a performance related.
RSCT misses heartbeat thru en12 for 10sec.
If it happens too often, then contact IBM tech support.
Set the heartbeat rate to "Slow".
Set the syncd rate from 10 sec to 60 sec.

EOF

No comments: